LXSC-13D3-25D3
Rotary Vane Wheel Single-jet Magnet-Drive
Dry-Dial Cold
(Hot) Water Meter |
|
Application:
This range of water
meter is used to measure the total quantity of cold
(hot)
potable water which
consumed in household or a resident unit, passing through the
pipeline.
Feature:
Dry type, magnet-drive.
small, light, free rotating register, easy and long term
clear reading. Magnet
resistance. Single-jet, Sensitive & Reliable. Measuring
accuracy conform to ISO 4064 Class B.
Working
Condition:
Water temperature:≤40℃ for cold water meter,
≤90℃ for hot water meter
Working pressure:≤1MPa
Compliance
With Standard:
ISO 4064 Class B
Indicating
Error:
a) In the lower zone from
Qmin inclusive up to but excluding Qt is ±5%
b) In the upper zone from Qt inclusive up to and
including Qs is ±2% |
|
Main
Technical Data: |
Type |
Meter Size
(mm) |
Class |
qs
Max
Flow |
qp
Nominal
Flow |
qt
Transitional
Flow |
qmin
Min
Flow |
Min Reading |
Max. Reading |
m3/h |
l/h |
m3 |
LXSC-13D3 |
13 |
A |
3 |
1.5 |
150 |
60 |
0.0001 |
99999 |
B |
120 |
30 |
LXSC-20D3 |
20 |
A |
5 |
2.5 |
250 |
100 |
0.0001 |
99999 |
B |
200 |
50 |
LXSC-25D3 |
25 |
A |
7 |
3.5 |
350 |
140 |
0.0001 |
99999 |
B |
280 |
70 |
|
|
Dimensions
And Weight: |
Meter Size
mm |
Length |
Width |
Height |
Connecting thread |
Weight
kg |
mm |
D |
13 |
110 |
77 |
85 |
G 3/4B |
0.8 |
20 |
130 |
77 |
85 |
G 1 B |
0.9 |
25 |
160 |
77 |
92 |
G 1-1/4 B |
1.47 |
|
|
|
Head
Loss Curve: |
|
|
|
|
Flow
Error Curve: |
|
|